YONGFAN HVAC - Premium Header
Engineered HVAC & Industrial Air Systems
YONGFAN HVACYOFAN HVAC Home
Contact Us – YONGFAN HVAC
Direct Engineering & Commercial Channels

Talk to YONGFAN About Your HVAC Requirement

Whether you are selecting a single HVAC component, preparing a comprehensive project quotation, replacing existing equipment, or coordinating cross-category product packages, YONGFAN can help identify the technical parameters required for the next step.

We partner with HVAC contractors, MEP engineers, system integrators, equipment distributors, and industrial plant owners worldwide. You do not need to know the final model number before reaching out — send the operating duty you already have.

HVAC engineering team reviewing technical project drawings

Engineering & Application Support

Direct duty-point verification, custom drawings, and commercial quotation support.

Commercial & Orders

Sales & Project Enquiries

  • Product Pricing & RFQ
  • Project Quotations & BOQ
  • Inventory & Lead Times
  • OEM & Custom Branding
  • Commercial Payment Terms
  • International Export Orders
  • Distributor Agreements
  • Global Tenders
Email: [Confirmed Sales Email]
Tel: [Confirmed Telephone]
Application Engineering

Technical Support & Sizing

  • Duty-Point Calculation
  • Aero / Hydraulic Sizing
  • Material Metallurgy Sizing
  • Retrofit Dimensional Match
  • CAD / Revit BIM Drawings
  • Submittal Technical Data
  • Installation Guidance
  • After-Sales & Spare Parts
Email: [Confirmed Technical Support Email]
Hours: [Confirmed Business Hours]
01 / Selection by Technical Duty

No Model Number Required: Send Operating Parameters

If you already have a specific model, send the product name and quantity. If you only have system working conditions, send the technical parameters below — our engineers will map them to the optimal equipment series.
AIRSIDE FANS

Ventilation Fans

  • Airflow (m³/h or CFM)
  • Static Pressure (Pa)
  • Operating Temperature
  • Application Environment
  • Power Voltage / Hz
AIR QUALITY

Air Filters

  • Filtration Grade (G1–U17)
  • Rated Airflow Volume
  • Face Dimensions (W×H×D)
  • Target Pressure Drop (ΔP)
  • Media / Frame Material
THERMAL

Heat Exchangers

  • Heat Load / Capacity (kW)
  • Primary In/Out Temps
  • Secondary In/Out Temps
  • Flow Rates & Pressure Drop
  • Water Chemistry / Media
GAS-PHASE

Chemical Filtration

  • Target Contaminant Gas
  • Gas Concentration (ppb/ppm)
  • Airflow / Room Volume
  • ISA 71.04 Target Class
  • Corrosion or Exhaust Duty
HYDRONICS

Hydronic Equipment

  • Design Water Flow (m³/h)
  • Required Pump Head (m)
  • System Working Pressure
  • Fluid Temperature Range
  • System Total Volume
Project Schedule Review

Send the Documents You Already Have

It is not necessary to reorganize existing files before contacting YONGFAN. Our engineering team can directly review your available project documents, identify missing duty parameters, and coordinate cross-category quotes.

Bill of Quantities (BOQ) Equipment Schedules Tender Specifications HVAC Layout Drawings Approved Vendor List (AVL)
Retrofit & Replacement

Existing Equipment Can Be the Starting Point

When replacing end-of-life units, replacement should be based on Function + Performance + Mechanical Interface. For fan and filter families, we provide direct physical dimensional matching for straightforward site drop-in.

Nameplate Photo Existing Manufacturer/Model Connection Flange Dimensions Motor Voltage / Frequency Physical Space Envelope
02 / International Project Coordination

OEM Customization, Global Logistics & Quality Audits

From private-label manufacturing and export crating to third-party witness testing, we support international engineering projects through transparent commercial and technical workflows.
Private Label & OEM

OEM & Customization

Project-tailored technical modifications and private branding:

  • Target market compliance (CE, UL, ISO, AMCA).
  • Custom dimensions, casing metals & motor specs.
  • Private-label branding and custom packaging.
  • Bespoke submittal documentation and test curves.
Worldwide Dispatch

International Logistics

Multi-modal shipping arrangements adapted to equipment scale:

  • Sea container (FCL / LCL), Air freight, and Land routes.
  • Standard commercial trade terms: EXW, FOB, CIF, DDP.
  • Heavy-duty reinforced wooden crating for export.
  • Customized customs declaration & certificate pack.
Quality Verification

Audits & Inspection

Factory verification protocols agreed prior to order release:

  • Onsite client visits & live virtual factory audits.
  • Customer witness testing for fans and hydronics.
  • Third-party pre-shipment inspection (SGS, TÜV).
  • Factory calibration and hydrostatic test certificates.
03 / Communication Guide

How to Get a More Accurate & Actionable Reply

Providing operational duty points rather than generic requests allows our engineering and commercial teams to respond immediately with verified technical selections, price schedules, and dimensional submittals.
Ventilation Fan Example
Generic Request: “Please send price for exhaust fan.”
Actionable Enquiry: “Need a mixed-flow fan for 18,000 m³/h at 650 Pa static pressure, 380 V / 50 Hz, roof-mounted with gravity damper.”
Air Filtration Example
Generic Request: “Need HEPA filter catalog and cost.”
Actionable Enquiry: “Airflow requirement is 3,200 m³/h, filter size 610 × 610 × 292 mm, H13 grade with gel seal, max initial ΔP < 220 Pa.”
Heat Exchanger Example
Generic Request: “Need plate heat exchanger quote.”
Actionable Enquiry: “Design capacity 500 kW. Primary side: 80/60°C hot water. Secondary side: 50/60°C. 316L plates, design pressure 1.6 MPa.”
04 / Quick Navigation

Choose the Right Contact & Resource Path

Connect directly with the specialized department or tool suited to your immediate project stage.
COMMERCIAL

I Need a Price Quote

Request a Quote
ENGINEERING

I Need Sizing Support

Selection Center
TECHNICAL

I Have a Tech Question

Technical Support
SUBMITTALS

I Need Drawings / CAD

Download Center
CATALOG

I Want Full Line Scope

Explore Products
05 / Start With What You Have

Ready to Discuss Your Project Requirement?

Whether you have a single model number, an equipment schedule, a full BOQ tender package, or simply an operating challenge that needs an engineered solution, contact YONGFAN today. Our engineers are ready to assist.

YONGFAN HVAC application engineers reviewing equipment specifications
YONGFAN M&E Engineering Office
HVAC System Components, Auxiliary Equipment & Global Supply Coordination.