Purification Fan Boxes | Integrated Multi-Stage Air Filtration | YONGFAN
Multi-Stage Air Treatment · Clean Air Delivery Rate

Purification Fan Boxes: Integrated Multi-Stage Air Filtration

Purification fan boxes combine low-noise centrifugal air movement with factory-integrated multi-stage filtration — primary coarse, secondary medium, terminal HEPA, and activated carbon odor adsorption — inside one sealed acoustic cabinet.

Compare YONGFAN DFX Purification configurations for electronics cleanrooms, pharmaceutical workshops, commercial kitchens, food processing, and healthcare clinics with verified filter module resistance (+150 to +350 Pa working ΔP), differential pressure monitoring, and quick-release access doors.

Filter GradesG1–G4 · F5–F8 · H11–H14 · Carbon
Efficiency SpectrumUp to 99.99% @ 0.3 µm · >90% Odor
Added Resistance+150 – +350 Pa Working Allowance
Cabinet SealingPositive-Seal Tracks · Quick Service
DFX purification fan box with multi-stage filter modules
Multi-Stage Air Treatment Primary G4 · Secondary F8 · HEPA H13/H14 · Carbon VOC Adsorption
01 / Aerodynamic Sizing

Purification Fan-Box Failures Start with Uncounted Filter Resistance

Every filter stage adds static pressure loss. Sizing the base fan from external duct loss alone causes severe airflow starvation once filters are installed.

A standard ventilation fan box operates across clean ductwork. In a purification fan box, the air must pass through coarse mesh, primary pleated panels, medium synthetic bags, and dense HEPA pleat packs.

Filters accumulate particulate matter over time. Sizing must account for dirty / working resistance — not just clean initial resistance — to ensure target airflow is delivered throughout the complete filter lifecycle.

Adding filter module working delta P (typically +150 to +350 Pa) to external duct static loss ensures the base centrifugal fan has adequate static head and motor horsepower.

Filter pressure drop and air handling unit

Clean vs Working ΔP

Sizing must account for loaded working pressure drop (e.g. F8 @ 170 Pa, HEPA @ 300 Pa) to prevent airflow decay between filter changes.

Lifecycle Sizing · Working ΔP Allowance

Progressive Filtration

Coarse pre-filters protect expensive medium and HEPA stages, extending HEPA life from months to several years.

Staged Protection · G4 → F8 → H13

Differential Pressure Gauges

Factory-mounted Magnehelic ΔP gauges on each stage provide visual indication for timely filter maintenance.

Magnehelic Gauges · Maintenance Alert
02 / Application Engineering

Configure the Treatment Train from the Target Contaminants

Optimized multi-stage filter combinations designed for electronics manufacturing, pharmaceuticals, commercial kitchens, and healthcare clinics.
Electronics Cleanrooms

G4 + F8 + H13 Clean Manufacturing

Multi-stage train removing coarse ambient dust (G4), fine atmospheric particulates (F8 90% @ 1 µm), and sub-micron particles with terminal H13 (99.95%) filtration.

Pharma & Chemical

G4 + F7 + Carbon + H14

Combines particulate removal with high-capacity activated carbon deep beds for VOC / odor vapor adsorption, followed by terminal medical-grade H14 (99.99%) filters.

Commercial Catering

Washable Mesh + G4 + Carbon

Washable nylon mesh traps grease droplets; G4 panels capture airborne soot; activated carbon panels achieve >90% kitchen cooking odor removal.

Hospitals & Healthcare

G4 + F8 + H14 Terminal Filtration

Medical-grade air treatment for clinic consultation rooms, isolation suites, and dental laboratories, trapping bacteria and airborne respiratory droplets.

Filter Module Stage Supplier Grade & Media Type Target Filtration Performance Air Resistance (ΔP Clean / Working) Action
Primary Coarse Stage Washable Nylon Mesh Screen Insects, fibers, and coarse dust particles > 50 µm
20 Pa Clean Resistance
Washable
Primary Pleated Panel G1 – G4 Synthetic Pleated Panel 40% – 90% arrestance of dust > 5 µm
30 – 50 Pa Clean · 70 Pa Working
Disposable
Medium Pocket Bag F5 – F8 Synthetic Meltblown Pocket 45% – 90% filtration efficiency @ 1.0 µm
70 – 150 Pa Clean · 170 Pa Working
High Capacity
High-Efficiency HEPA H11 – H14 Glass Microfiber Mini-Pleat 95% – 99.99% cleanroom efficiency @ MPPS (0.3 µm)
180 – 220 Pa Clean · 300 Pa Working
Cleanroom Grade
Odor Adsorption Activated Carbon Panel / Bag Bed > 90% odor, VOC, and solvent vapor removal
25 – 40 Pa Working Resistance
Refillable/Replace
Auxiliary Heating PTC Ceramic / Heat-Pipe Module Electric winter air tempering and humidity reduction
Negligible Resistance (≤ 10 Pa)
Optional Winter
03 / Engineering Interchangeability

Changing Purification Suppliers Requires Module-by-Module Verification

Ensure replacement purification units match filter holding frame dimensions, gasket sealing compression, and differential pressure switch connections.
Integrity 01 / Frame Sealing

Zero Air Bypass & Gasket Compression

Filter efficiency is compromised if air bypasses around holding frame edges. DFX Purification cabinets utilize precision knife-edge or extruded gasket clamping tracks that ensure 100% positive sealing for HEPA and carbon modules.

Standard filter module sizes (e.g. 592 × 592 mm / 24″ × 24″) ensure universal replacement availability worldwide.

Filter clamping track and gasket compression
Integrity 02 / Maintenance Access

Quick-Release Hinged Doors & Service Clearance

Purification cabinets require frequent filter inspection and replacement. DFX units feature insulated hinged access doors with cam-lock handles on the service side.

Maintain at least one cabinet width of clear space on the access side to allow maintenance technicians to withdraw full-size 600 mm pocket filters and heavy carbon trays.

Hinged access door and filter maintenance
04 / Procurement Protocol

What Project Inputs Are Required for Purification Box Sizing?

Essential sizing parameters to confirm before specifying DFX Purification fan box models and filter media trains.
Engineering Sizing Checklist

10 Key Inputs for DFX Purification Quotation

Submitting target particle sizes, VOC concentrations, airflow, and duct static pressure allows our team to calculate total system resistance and select the optimal base fan motor.

1. Required Clean Airflow (m³/h / CFM)
2. External Duct Static Pressure (Pa ΔPs)
3. Target Contaminant: Dust, Oil Mist, VOC, Odor
4. Required Filter Train: G4 / F8 / H13 / Carbon
5. Cleanroom ISO Class / Healthcare Grade
6. Magnehelic Differential Pressure Gauges
7. Auxiliary PTC Heating Module Requirement
8. Power Supply (220V / 380V / 50Hz)
9. Service Door Access Side (Left vs Right)
10. Casing Breakout Noise Limit (dB(A))
05 / Quality Control

YONGFAN Purification Cabinet Fabrication & Sealing Quality

Air-tight casing construction, positive filter gasket clamping, and factory leakage testing guarantee cleanroom-grade performance.
Zero Bypass

Positive-Seal Filter Tracks

Filter holding channels feature compression latching systems that guarantee 100% gasket compression, preventing bypass of unfiltered air around media edges.

Airtight Casing

Class L1 Casing Leakage

Double-skin insulated panels and closed-cell EPDM gaskets achieve EN 1886 Class L1 airtightness under ±1000 Pa operating static pressure.

Factory Tested

Aerosol & ΔP Verification

Every HEPA stage is verified for initial pressure drop and particulate filtration efficiency using calibrated optical particle counters prior to shipment.

Traceability

Serialized Quality Dossier

Supplied complete with filter test certificates, motor electrical test logs, and dimensioned 3D CAD/BIM submittal models.

Bespoke Air Treatment Submittals: Filter pressure drop calculation sheets, chemical VOC adsorption data, and wiring schematics provided. Configured Dispatch: Lead time quoted based on required filter stages (G4 to H14), carbon mass, and motor power.
06 / Technical Q&A

Purification Fan Boxes Frequently Asked Questions

Direct engineering answers covering filter stage selection, HEPA pressure sizing, carbon odor removal, and clinic configurations.

Which filter stages are available in the YONGFAN DFX Purification Fan Box?

DFX Purification units support washable nylon mesh (20 Pa), primary G1–G4 (70 Pa working), secondary F5–F8 (170 Pa working), HEPA H11–H14 (300 Pa working), activated carbon odor filters, and auxiliary PTC heating.

How do I properly size the fan motor when H13 or H14 HEPA is added?

Add 250 to 300 Pa working resistance to external duct static loss. Sizing the base fan without filter working delta P causes severe airflow reduction.

Can I combine primary, medium and HEPA stages in one cabinet?

Yes. Multi-stage DFX Purification cabinets accommodate 2-stage, 3-stage, or 4-stage filter trains in series with dedicated service doors for each stage.

Which configuration does YONGFAN recommend for electronics cleanrooms?

We recommend a G4 pre-filter + F8 secondary pocket filter + H13 terminal HEPA filter configuration, capturing 99.95% of airborne particles ≥ 0.3 µm.

Which configuration is recommended for commercial kitchens?

We recommend washable nylon mesh + G4 pleated panels + activated carbon adsorption modules to remove grease soot and >90% cooking odors.

How do I know when filters need replacement?

DFX units can be equipped with differential pressure Magnehelic gauges or pressure switches that trigger BMS alerts when working ΔP thresholds are reached.

Are standard filter sizes used for easy replacement?

Yes. All DFX filter modules use standard international dimensions (e.g. 592 × 592 mm / 24″ × 24″), ensuring low-cost replacement media availability.

Can DFX Purification replace a central Air Handling Unit (AHU)?

DFX Purification provides dedicated air movement and filtration for specific zones or clean rooms. For central chilled-water thermal cooling and full humidity control, a central AHU is used.

07 / Application Engineering Handoff

Select the Right DFX Purification Fan Box for Your Facility

Send your required clean airflow, target contaminants, room cleanliness class, and duct drawings — our application engineers will configure the optimal multi-stage filter train and supply certified technical submittals.

Clean Airflow (m³/h / CFM) External Static Pressure (Pa) Primary G4 · Secondary F8 Terminal HEPA H13/H14 Activated Carbon Odor Module Differential ΔP Gauges
YONGFAN filtration application engineers reviewing purification fan box submittals
Direct Technical Filtration Support
Filter lifecycle ΔP calculations, aerosol submittals & 3D BIM models.