Industrial Gas-Phase Filtration | YONGFAN
Molecular Contamination Control · ISA S71.04 Class G1 · Fresh Air, Recirculation & Exhaust · 850 to 100,000+ m³/h

Industrial Gas-Phase Filtration: Targeted Molecular Adsorption & Chemisorption

Gas-phase filtration should be selected from the contaminant, airflow direction and protection objective—not from a generic “activated carbon filter” label.

Compare YONGFAN PSA fresh-air chemical filtration units (850–34,000 m³/h), PSA-PG high-airflow units (1,700–68,000 m³/h), DBS corridor positive-pressure/recirculation units, CA indoor recirculation units (850–6,800 m³/h with MediaPAK PK-12 modules), WGP industrial exhaust gas treatment (to 100,000+ m³/h), and OGP wastewater odor capture enclosures.

PSA Fresh-Air 850–34,000 m³/h · 99.5% Eff
PSA-PG High Flow 1,700–68,000 m³/h · G1 Target
CA Recirculation 850–6,800 m³/h · MediaPAK
WGP Exhaust To 100,000+ m³/h · Carbon+Chem
Industrial chemical filtration units and deep-bed gas phase scrubbers at petrochemical plant
Molecular Gas-Phase Systems PSA Fresh Air · PSA-PG High Flow · DBS Corridor · CA Recirculation · WGP Industrial Exhaust · OGP Odor
01 / Molecular Contaminant Analysis

Molecular Contaminants Require a Different Removal Strategy From Dust

A control room or wastewater facility can have low dust levels while H2S, SO2, chlorine, mercaptans, or VOCs attack electronics or cause severe environmental odor complaints.
Chemical filter media pellets, potassium permanganate impregnated alumina, and activated carbon beds
Targeted Chemisorption Media

KOH-Impregnated (PCB) · Permanganate (CPB) · High-CTC Carbon

PSA, PSA-PG, DBS, and CA protect indoor electronic spaces to ISA S71.04 Class G1; WGP treats contaminated industrial emissions before discharge.

HEPA Filter Gas Transparency

Assuming HEPA filters capture molecular gases; toxic H2S, SO2, and VOCs pass right through particle filters and corrode copper/silver circuit tracks.

Impact: Severe electronics corrosion & unmitigated gas emission

Intake vs Exhaust Equipment Confusion

Installing a protected-room fresh-air PSA unit on a heavy industrial exhaust stack, or using an open exhaust scrubber for pressurized room intake.

Impact: Rapid media destruction & failed environmental compliance

Generic Carbon Media Mismatch

Using standard virgin carbon for acid gases (NOx, SO2, chlorine) where specialized chemical chemisorption (permanganate CPB) is required.

Impact: Instant contaminant breakthrough & zero gas removal

Uncaptured Source Odor Bypass

Increasing exhaust treatment unit airflow on wastewater tanks without installing OGP source-capture covers allows odor to escape into atmosphere.

Impact: Wasted fan power & persistent community odor complaints

Four Targeted Gas-Phase Operating Archetypes

Fresh air intake, indoor recirculation, high-capacity exhaust treatment, and source capture.

01 / Fresh Air Corrosion PSA & PSA-PG multi-stage fresh air intake units for ISA S71.04 Class G1
02 / Indoor Recirculation DBS & CA room purifiers targeting internal gas ingress and door openings
03 / Exhaust Gas Treatment WGP high-volume multi-mechanism treatment with deep carbon & chemisorption beds
04 / Source Capture Enclosure OGP modular FRP/SS/Polycarbonate enclosures for wastewater tanks & channels
02 / Portfolio Showcase

Industrial Gas-Phase Product Families

Detailed engineering review of YONGFAN’s fresh-air units, recirculation purifiers, and exhaust treatment systems.
01 · PSA Fresh-Air Fresh-Air Corrosion Control · 850–34,000 m³/h

PSA Chemical Filtration Unit

Standard fresh-air corrosion-control platform for electrical control rooms (850–34,000 m³/h, 99.5% removal efficiency for target gases, ISA S71.04 Class G1 target, 2,000 Pa casing rating, <1% leakage at 1,000 Pa). Filtration train: G4 pre-filter + two-stage gas-phase (PK12-PCB KOH & PK12-CPB KMnO4) + F8 final particulate filter.

Airflow Range
850 to 34,000 m³/h
Removal Efficiency
99.5% for Listed Contaminants
Casing Rating
2,000 Pa Strength / <1% Leakage @ 1,000 Pa
Filtration Stages
G4 Pre + 2× Chemical Stages + F8 Final
Primary Applications

Petrochemical control rooms, refinery switchgear rooms, paper mill motor control centers, and substation fresh air intakes.

02 · PSA-PG High Flow High-Airflow Fresh Air · 1,700–68,000 m³/h

PSA-PG High-Airflow Chemical Filtration Unit

High-capacity corrosion-protection platform delivering twice the airflow of standard PSA units (1,700–68,000 m³/h, 0.75–37 kW, 380 V 50 Hz, 2,000 Pa casing rating, <1% leakage at 1,000 Pa). Consolidates large fresh-air demand into fewer high-capacity skids to reduce duct branches and maintenance points.

Airflow Capacity
1,700 to 68,000 m³/h per Unit
Motor Power
0.75 to 37 kW · 380 V / 50 Hz
Target Standard
ISA S71.04 Class G1 Compliance
Media Life Ref
PCB Media up to 2 Years Typical
Primary Applications

Large petrochemical central control halls, multi-rack data centers, battery manufacturing dry rooms, and major chemical plants.

03 · DBS Corridor Positive Pressure or Recirculation · Top-Fill / Bottom-Drop

DBS Chemical Filtration Unit

Configured for indoor or corridor installation. Operates in positive-pressure fresh air mode or indoor recirculation cleaning mode. Features G4 upstream + chemical media + F8 downstream filtration with a top-fill / bottom-discharge loose media design for rapid on-site media replacement.

Operating Modes
Positive Pressure Fresh Air or Room Recirculation
Media Maintenance
Top-Fill / Bottom-Discharge Loose Media
Removal Rating
99.5% Efficiency for Documented Gases
Control Interlocks
Local/Remote Start, Gas Detector & DCS Status
Primary Applications

Corridor equipment rooms, localized PLC/DCS cabinets, server rooms, and industrial electronics rooms.

04 · CA Recirculation Dedicated Recirculation · 850–6,800 m³/h · MediaPAK

CA Indoor Recirculation Chemical Filtration Unit

Self-contained room air purifier (850–6,800 m³/h across 500V, 1000V, 2000V, 4000V models) with built-in VFD, LCD control, and sound-treated fan (<65 dB). Utilizes rail-mounted MediaPAK PK-12 slide-in modules for clean, fast replacement without handling loose media.

Airflow Models
500V (850 m³/h), 1000V (1,700), 2000V (3,400), 4000V (6,800)
Media Modules
Rail-Mounted Pre-Filled MediaPAK PK-12
Acoustic Limit
<65 dB(A) Sound-Treated Housing
VFD Control
Built-In Variable Frequency Drive & LCD
Primary Applications

Continuously cleaning recirculated air in occupied control rooms, laboratory analyzer shelters, and server rooms.

05 · WGP Exhaust Industrial Exhaust Scrubber · To 100,000+ m³/h

WGP Exhaust Gas Treatment Unit

Heavy-duty industrial exhaust treatment for complex contaminated gas streams (several thousand to 100,000+ m³/h custom). Features G4 particulate pre-filtration, deep coal-based activated carbon (iodine ≥1,000 mg/g, hardness ≥95%, CTC ≥60%), and multi-stage chemical chemisorption beds with combustible/toxic gas detection interlocks.

Airflow Capacity
Several Thousand to 100,000+ m³/h Custom
Removal Efficiencies
H2S ≥99%, SO2 ≥99%, TVOC ≥95%, Formaldehyde ≥96%
Carbon Quality
Iodine ≥1,000 mg/g · Hardness ≥95% · CTC ≥60%
Safety Controls
Toxic/Combustible Gas Detectors & Fire Interlocks
Primary Applications

Hazardous waste storage exhaust, chemical process vents, wastewater odor stacks, pharmaceutical synthesis, and food processing.

06 · OGP Odor Enclosure Source Capture Capping · 1,000–10,000 m³/h · 150 Pa ESP

OGP Odor-Control Enclosure System

Modular source collection and capping system for wastewater treatment tanks, clarifiers, and sludge channels. Fabricated from FRP, stainless steel, or polycarbonate; captures fugitive odor and routes it directly to WGP treatment equipment (1,000–10,000 m³/h models, 150 Pa ESP).

Airflow Models
1,000 to 10,000 m³/h Capture Capacity
Static Pressure
150 Pa External Static Pressure
Cover Materials
FRP (Fiberglass), Stainless Steel, Polycarbonate
System Chain
Source Capture → Extraction Duct → WGP Scrubber
Primary Applications

Wastewater treatment clarifiers, sludge dewatering rooms, equalization basins, and industrial sewer collection.

03 / Selection Routing

Gas-Phase Product Routing by System Objective

Match the project protection objective to the appropriate YONGFAN gas-phase product route.
System ObjectiveProduct RouteDocumented Capacity / BoundaryFirst Data to Confirm
Treat fresh air for a protected control roomPSA850–34,000 m³/h · ISA G1 targetFresh-air volume & full gas analysis
Treat high-volume fresh air for large hallsPSA-PG1,700–68,000 m³/h per unitTotal fresh-air demand & unit redundancy
Indoor/corridor positive pressure or recircDBSFunction documented; project sizedRoom mode, gas load & installation space
Standalone indoor room recirculationCA850–6,800 m³/h · MediaPAKRoom volume, air-change target & gas mix
Treat outgoing industrial / process exhaustWGPSeveral thousand to 100,000+ m³/h customExhaust airflow + full gas composition
Capture wastewater tank fugitive odorOGP + WGPOGP 1,000–10,000 m³/h modelsTank geometry, capture airflow & gas load
04 / Procurement Protocol

Information Required for Gas-Phase System Sizing

Provide target gas species, normal/peak concentrations, airflow rate, air direction (fresh/recirc/exhaust), and temperature/RH.
STEP 01

Contaminant Analysis

List gas names (H2S, SO2, Cl2, NOx, VOCs, mercaptans), normal/peak concentrations (ppm or mg/m³).

STEP 02

Air Path Direction

Define Fresh Air Intake (PSA/PSA-PG), Room Recirculation (CA/DBS), or Outgoing Exhaust (WGP).

STEP 03

Media Chemistry

Select KOH-impregnated (PCB), permanganate-impregnated (CPB), or high-CTC coal-based carbon.

STEP 04

Safety & Monitoring

Specify toxic gas detector interlocks, airtight motorized shutoff dampers, and copper/silver coupons.

Engineering Handoff

Submit Gas-Phase Contaminant Data for Media Sizing

YONGFAN chemical filtration engineers will calculate media bed depths, verify gas contact times, check casing leakage ratings, and size fan static pressures.

Target Gas List & Peak Concentrations (ppm / mg/m³)
Airflow Rate (m³/h) & Air Direction (Fresh / Recirc / Exhaust)
Operating Temperature (°C) & Relative Humidity (% RH)
Environmental Target: ISA S71.04 Class G1 or Emission Limits
Installation Layout: Outdoor Skid, Indoor Floor, or Corridor
Monitoring: Real-Time Monitors, Reactivity Coupons, or Gas Sensors
05 / Manufacturing QA

ISO 10121 Testing & Gas-Phase Quality Standards

Housings undergo 2,000 Pa structural and <1% leakage tests; chemical media is UL/SGS fire-certified with full SDS documentation.
Casing QA

2,000 Pa Casing Integrity Test

PSA, PSA-PG, and DBS housings are certified to 2,000 Pa casing strength with <1% leakage at 1,000 Pa differential pressure.

Media QA

ISO 10121 Challenge Testing

Chemical media batches are tested per ISO 10121-1/-2 for single-pass gas removal efficiency and capacity.

Safety QA

UL / SGS Fire Safety & SDS

Chemical media and activated carbon hold UL/SGS fire safety certification and complete chemical Safety Data Sheets.

Exhaust QA

GB/T 14294 & GB/T 34012 Tests

WGP scrubbers undergo third-party whole-unit testing for airflow, total pressure, and purification efficiency.

PSA & CA Units: Standard PSA units and CA purifiers dispatched in 15–25 working days. Custom WGP Systems: WGP exhaust scrubbers and OGP custom tank enclosures engineered to order.
06 / Engineering Knowledge

Industrial Gas-Phase Filtration FAQ

Direct engineering answers regarding HEPA limitations, PSA vs WGP, DBS vs CA, and media service life.

Can a HEPA filter remove H2S, SO2 or VOCs?

No. HEPA filters only remove suspended solid/liquid particles. Molecular gases require gas-phase chemical media tailored to the specific gas chemistry.

What is the main difference between PSA and WGP?

PSA treats incoming outdoor air to protect indoor electronics from corrosion. WGP treats contaminated outgoing process or wastewater exhaust before atmospheric discharge.

When should I choose PSA-PG instead of PSA?

Choose PSA-PG when fresh-air demand is very high (1,700–68,000 m³/h per unit). It consolidates airflow into fewer high-capacity units to simplify ductwork and maintenance.

What is the difference between DBS and CA?

DBS is designed for corridor/plant rooms and can provide positive-pressure fresh air or recirculation with loose media. CA is a dedicated quiet indoor recirculation purifier with slide-in MediaPAK modules.

Can CA replace the fresh-air system?

No. CA continuously cleans recirculated room air, but it does not supply the outdoor air required for room ventilation or positive pressurization.

What gases can WGP target?

WGP targets H2S (≥99%), SO2 (≥99%), TVOCs (≥95%), formaldehyde (≥96%), chlorine, ammonia, NOx, mercaptans, and mercury vapor.

How is WGP sized?

From exhaust airflow, gas species, and peak concentrations. The depth and stage count of the activated carbon and chemical chemisorption beds are customized for that load.

What is OGP used for?

OGP is an odor-source capping/enclosure system for wastewater tanks and channels. It captures fugitive emissions and routes them to WGP for treatment.

How often should chemical media be replaced?

There is no universal calendar date. Typical documented references are 1–2 years, but actual replacement depends on gas concentration, airflow, humidity, and operating hours.

Does one corrosion-control unit guarantee ISA G1 inside the room?

No. The unit delivers G1-grade air, but room environmental quality also depends on room leakage, positive pressurization, door opening frequency, and internal sources.

07 / Application Boundaries

Industrial Gas-Phase Engineering Boundaries

Key operational boundaries to respect when designing industrial gas-phase filtration systems.
Boundary 01 / Intake vs Exhaust

Do Not Merge PSA & WGP

Never use protected-room fresh-air units (PSA/PSA-PG) for outgoing process emissions, and do not use exhaust scrubbers for pressurized room intake.

Boundary 02 / Environmental G1

Room Envelope Dependent

ISA S71.04 Class G1 is a complete room target; one cabinet does not independently guarantee G1 without positive pressure and sealed penetrations.

Boundary 03 / Efficiency Conditions

99.5% Test Context

Supplier-published 99.5% gas removal values apply to documented test conditions and media configurations; verify against site gas concentrations.

Boundary 04 / Source Capture

OGP Is Not Removal

OGP is a mechanical enclosure for collecting odor; WGP performs the actual gas removal and emission treatment duty.

08 / Engineering Handoff

Plan Your Industrial Gas-Phase Filtration System

Send your gas analysis, concentration data, airflow rates, and application objective. YONGFAN chemical filtration engineers will select media blends, calculate contact times, size fan static pressures, and provide certified submittals.

PSA Fresh-Air Chemical Units (850–34,000 m³/h)PSA-PG High-Airflow Units (1,700–68,000 m³/h)CA Indoor Recirculation (MediaPAK PK-12 Modules)DBS Corridor Units (Top-Fill / Bottom-Discharge)WGP Exhaust Treatment (To 100,000+ m³/h Custom)OGP Wastewater Odor Enclosures (1,000–10,000 m³/h)KOH-Impregnated (PCB) & Permanganate (CPB) MediaISA S71.04 Class G1 Corrosion Verification
YONGFAN chemical filtration engineers analyzing gas chromatography data and sizing chemical media beds
Direct Chemical Engineering Handoff
Gas contact time modeling, chemisorption media selection & casing leakage test submittals.