Recirculation Chemical Filtration Units | CA & DBS Series | YONGFAN
Indoor Air Polishing · CA & DBS · ISA S71.04 G1

Recirculation Chemical Filtration: Clean Indoor Air & Eliminate Infiltrated Gas

Fresh-air systems only treat make-up air. Corrosive gases entering through doors, cable penetrations, or equipment seals linger in server rooms, continuing circuit degradation.

YONGFAN CA and DBS units continuously polish indoor air, removing H₂S, SO₂, Cl₂, NOx, and formaldehyde via plug-in MediaPAK PK-12 modules or deep-bed top-fill designs.

CA Airflow 850 – 6,800 m³/h
Dual Function Recirc / Pos-Pressure
Acoustic Limit <65 dB (VFD Mode)
Media Format PK-12 Cartridges / DBS
Mission-critical server room and data center protected by recirculation chemical filtration
Indoor Air Quality Polishing Continuous Chemisorption for Server Rooms, DCS Racks & Archives
01 / Infiltration Dynamics

Why Outdoor Treatment Alone Leaves Server Rooms Corroding

Corrosive gases enter through door traffic, cable trays, and envelope gaps. Fresh air units cannot cycle indoor room volume quickly enough to neutralize internal spikes.
Data center server racks operating in continuous low-corrosion environment
Room-Level Polishing Kinetics

Continuous Multi-Pass Air Cleaning

Recirculation units cycle room volume 6 to 12 times per hour, rapidly decaying infiltrated molecular gas concentrations below ISA S71.04 Class G1 limits.

Door & Cable Infiltration

Corrosive gas enters every time personnel enter. Outdoor-only systems never scrub the trapped indoor air surrounding active servers.

Impact: Localized corrosion pockets inside server racks

Recirculation ≠ Pressurization

Pure recirculation units do not bring outdoor air in. Positive room pressure requires fresh-air make-up (PSA) or DBS in positive-pressure mode.

Impact: Confusion between room cleaning & pressurization

Acoustic Disturbance

High-airflow blowers placed in occupied control rooms generate intrusive noise. CA uses acoustic lining and VFD control to remain below 65 dB.

Impact: Control room operator fatigue & noise complaints

Media Replacement Downtime

Refilling loose media inside live data centers creates dust risk. CA uses pre-packed, rail-mounted MediaPAK PK-12 slide-in cartridges.

Impact: Zero-dust cartridge replacement in live facilities

Dual Chemistry Support for Complex Industrial Atmospheres

Matched to specific target gases in petrochemical, pulp/paper, and electronics rooms.

PK12-PCB KOH ≥8% · >20% H₂S, >10% SO₂, >10% Cl₂
PK12-CPB NaMnO₄ ≥12% · >18% NOx, >4% HCHO, >20% VOC
VFD Control Adjust Airflow to Measured Room Load
Quiet Duty <65 dB Sound Attenuation
02 / Product Breakdown

CA Standalone Purifier & DBS Dual-Mode Unit

Select between CA dedicated room-recirculation purifiers with slide-in cartridges and DBS corridor/cabinet units with positive-pressure capability.
CA Series · Dedicated Recirculation 850 to 6,800 m³/h · <65 dB

CA Indoor Recirculation Chemical Filtration Unit

The CA Series is a dedicated in-room air purification unit designed for server rooms, computer centers, and archives. Drawing room air through grilles, it passes air through G4 pre-filters, rail-mounted MediaPAK PK-12 modules (324 Pa), and F8 post-filters before returning clean Class G1 air.

Airflow Range
850 – 6,800 m³/h (4 Standard Models)
Media Handling
Slide-in MediaPAK PK-12 Cartridges
Control & Sound
Integrated VFD + LCD · <65 dB Noise
Mobility
Vertical Units Available with Heavy Casters
CA Standard Model Specs
CA-500V 850 m³/h · 0.75 kW · 265 kg
CA-1000V 1,700 m³/h · 1.5 kW · 272 kg
CA-2000 3,400 m³/h · 2.2 kW · 419 kg (H)
CA-4000V 6,800 m³/h · 4.0 kW · 720 kg

*All models 380 V / 50 Hz, 25 Pa ESP.

DBS Series · Dual-Mode Unit Positive-Pressure OR Recirculation

DBS Chemical Filtration Unit

The DBS Series is an indoor or corridor-mounted unit that operates in either positive-pressure supply mode or recirculation mode. It uses flanged duct connections and a top-fill / bottom-discharge bulk chemical bed, providing 249 Pa available ESP with <1% casing leakage at 1,000 Pa.

Operating Modes
Positive-Pressure Supply OR Recirculation
Available ESP
249 Pa for Ducted Room/Cabinet Delivery
Media Handling
Top-Fill / Bottom-Discharge Bed Design
Casing Rating
2,000 Pa Structural · <1% Leakage
DBS Structural Features
  • Double-skin cold-rolled steel with 30 mm PU insulation
  • 2 mm steel or stainless base frame
  • 220 V or 380 V / 50 Hz direct-drive IP55 fans
  • Flanged inlet/outlet for ducted enclosure connection
03 / Selection Routing

CA vs. DBS: Family Comparison Matrix

Match equipment role to room ventilation architecture and servicing requirements.
Feature CA Indoor Recirculation Unit DBS Chemical Filtration Unit
Primary Role Dedicated room recirculation air polishing Positive-pressure fresh air supply OR recirculation
Documented Airflow 850 to 6,800 m³/h (4 standard models) Project-engineered per quotation
Media Format Pre-packed MediaPAK PK-12 slide-in modules Top-fill / bottom-discharge bulk media bed
Pressure Capability 25 Pa ESP (free-room return/supply grilles) 249 Pa ESP (ducted room/cabinet delivery)
Control Interface Integrated VFD + LCD panel Direct / DCS status integration
Best Application Live server rooms, control rooms with existing fresh air Equipment corridors, cabinet pressurization, compact AHUs
04 / Procurement Protocol

Information Required for Recirculation Sizing

Room dimensions, door-opening frequency, measured gas concentrations, and acoustic targets dictate required air changes and media volume.
STEP 01

Room Volume (m³)

Provide length, width, and ceiling height of the protected room.

STEP 02

Gas Challenge Profile

Identify target contaminants (H₂S, SO₂, NOx, VOCs, formaldehyde).

STEP 03

Pressure Strategy

Confirm if positive pressure is existing or required from this unit.

STEP 04

Maintenance Format

Choose slide-in MediaPAK cartridges (CA) or bulk refill (DBS).

Engineering Handoff

Submit Room Data for CA / DBS Selection

YONGFAN engineers will calculate room air-change rates and recommend the optimal media formulation.

Room Volume (m³ / sq ft)
Target Gases: H₂S, NOx, SO₂, HCHO
Unit Role: Recirc vs. Pos-Pressure
Noise Target (<65 dB)
MediaPAK PK-12 vs Bulk Fill
Optional Corrosion Coupons
05 / Manufacturing Verification

Quality Verification & Module Seal Testing

CA and DBS units are individually tested for airflow balance, casing leakage, and MediaPAK guide-rail alignment before release.
MediaPAK QA

Zero-Bypass Rail Fit

MediaPAK guide rails and module perimeter seals are checked to ensure 100% of air passes through chemical granules.

Acoustic QA

<65 dB Sound Verification

Internal blowers and acoustic insulation are checked across full VFD speeds to guarantee quiet operation in server rooms.

Casing QA

<1% Leakage on DBS

DBS casings undergo pressure testing against 2,000 Pa structural and <1% leakage benchmarks at 1,000 Pa.

Chemical QA

Assayed Active Media

Chemical media is tested for active KOH / NaMnO₄ percentage and flame retardancy per UL 900 standards.

Fast Module Reordering: Replacement MediaPAK PK-12 cartridges are packed in sealed cartons for rapid field changeouts. Trade Terms: EXW, FOB, CIF, and DDP export delivery supported worldwide.
06 / Engineering Knowledge

Recirculation Chemical Filtration FAQ

Direct engineering answers regarding CA and DBS applications, media replacement, noise, and pressurization.

Which YONGFAN unit is dedicated to room recirculation?

The CA Indoor Recirculation Chemical Filtration Unit is specifically designed to polish air already inside the protected room.

When should I choose DBS instead of CA?

Choose DBS when positive-pressure filtered make-up air is required in addition to chemical filtration, or when ducted connections are needed.

Does CA bring outdoor air into the room?

No. CA is a pure recirculation unit. Pair it with PSA or a positive-pressure DBS configuration when fresh outdoor air is required.

What is MediaPAK PK-12?

It is the pre-filled, rail-mounted chemical-media module used in CA units, replaced as a complete cartridge to eliminate in-room dust.

Which media handles NOx and formaldehyde?

PK12-CPB (sodium permanganate / KMnO₄) targets NOx, NO₂, formaldehyde, and trichloroethane alongside acid gases.

Can CA airflow be adjusted?

Yes. CA includes a built-in VFD and LCD control, allowing airflow to be matched to room volume and measured gas load.

07 / Application Boundaries

CA & DBS Engineering Boundaries

Clear distinction between indoor polishing, positive-pressure fresh air, and process exhaust scrubbing.
Boundary 01 / Fresh Air Intake

Not High-CFM Fresh Air

For large outdoor fresh-air make-up systems, select PSA or PSA-PG.

Boundary 02 / Exhaust Discharge

Not for Process Exhaust

CA and DBS are indoor room units. For contaminated exhaust discharge to the atmosphere, select WGP Series.

Boundary 03 / CA Pressurization

CA Does Not Pressurize

CA operates within closed room boundaries; it cannot create positive room overpressure without fresh-air units.

Boundary 04 / Media Life Sizing

Gas-Specific Life

Media replacement intervals depend on continuous infiltration rates and door traffic, not room square footage alone.

08 / Engineering Handoff

Select the Right Recirculation Unit for Your Server Room

Send your room volume, gas exposure risks, and layout constraints. YONGFAN engineers will calculate air-change rates, select the optimal PK-12 media formulation, and provide dimensional submittals.

Airflow: 850–6,800 m³/h MediaPAK PK-12 Slide-in VFD <65 dB Quiet Mode PK12-PCB / PK12-CPB Media DBS Dual-Mode Option ISA S71.04 Class G1 Target
YONGFAN application engineers reviewing server room chemical filtration layouts
Direct Application Engineering Support
Room air-change calculations, media loading models & GA submittals.