Duct Centrifugal Fans | Low-Profile In-Line Air Movement | YONGFAN
Ultra-Low Profile Ceiling Plenums · In-Line Volute Centrifugal

Duct Centrifugal Fans: Compact In-Line Centrifugal Air Movement

When ceiling plenums are too tight for standard rectangular fan boxes, DFS Series duct centrifugal fans provide high static pressure air movement in an ultra-low profile in-line casing.

Compare YONGFAN DFS-I series models (DFS-I-12 through DFS-I-37) across airflow (300 to 4,500 m³/h), total pressure (120 to 850 Pa), low sound ratings (≤45 to ≤65 dB(A)), and shallow depth ceiling void installations across commercial offices, hotels, and schools.

DFS-I Model RangeDFS-I-12 through DFS-I-37
Airflow Spectrum300 – 4,500 m³/h
Static Pressure120 – 850 Pa ΔPs
Housing ProfileUltra-Shallow Ceiling Depth
DFS series compact duct centrifugal fan in ceiling void
DFS In-Line Centrifugal Ultra-Low Profile Depth · In-Line Rectangular Spigots · Up to 850 Pa Static Head
01 / Selection Methodology

Compact Duct Fans Still Fail When the Operating Point Is Wrong

A compact duct fan cannot overcome tight ceiling losses if selected purely from free-air CFM without verifying static pressure capability across branch ducts.

In modern commercial buildings, ceiling plenum heights are constrained by structural beams, electrical trays, and plumbing lines. Standard centrifugal scroll fans cannot physically fit into these spaces.

The DFS Series solves this spatial conflict by flattening the centrifugal volute into an in-line rectangular casing. Air enters axially and is accelerated through a double-inlet forward-curved impeller, generating static pressure up to 850 Pa in a fraction of standard cabinet height.

Sizing requires matching both available ceiling height and calculated duct static pressure.

Ceiling plenum duct fan installation

Ultra-Shallow Ceiling Depth

Fits directly into shallow 250–400 mm ceiling plenums above false ceilings in hotels, offices, and residential towers.

Low Profile · Ceiling Space Saving

Centrifugal Pressure Head

Develops up to 850 Pa static pressure, easily overcoming resistance from multi-room extract grilles, silencers, and long flex ducts.

Forward Centrifugal · 120–850 Pa

Direct Flange Bolting

Integrated rectangular duct flanges on both inlet and discharge simplify connection without requiring complex offset transitions.

In-Line Flanges · Fast Installation
02 / Model Spectrum

Choose the DFS-I Size from the Actual Pressure Duty

Categorized DFS-I models tailored for small ensuite exhausts, commercial multi-room offices, and high-flow branch distribution.
Small Duct Systems

DFS-I-12 & DFS-I-15

Covers 300 to 1,200 m³/h and 120 to 350 Pa. Ideal for hotel ensuite bathrooms, residential toilet extract, and small private meeting rooms.

Medium Office Runs

DFS-I-20, 22 & 25

Covers 1,200 to 2,800 m³/h and 250 to 550 Pa. Engineered for multi-room commercial office supply, school classrooms, and clinic ventilation.

Larger Commercial

DFS-I-28 & DFS-I-30

Covers 2,500 to 3,800 m³/h and 350 to 700 Pa. Delivers higher static pressure for long multi-elbow duct runs and sound attenuator banks.

Maximum Capacity

DFS-I-37 Maximum Flow

Reaches up to 4,500 m³/h and 850 Pa total pressure. The highest capacity unit in the DFS-I family for central branch collection.

Model Code Airflow Capacity (m³/h) Static Pressure Range (Pa) Speed (r/min) Motor Power (kW) Sound Level (dB(A)) Action
DFS-I-12 300 – 850 m³/h
120 – 280 Pa
1,400 r/min 0.08 kW ≤ 45 dB(A) Configure
DFS-I-15 600 – 1,350 m³/h
150 – 350 Pa
1,400 r/min 0.12 kW ≤ 48 dB(A) Configure
DFS-I-20 1,100 – 2,100 m³/h
200 – 450 Pa
1,400 r/min 0.25 kW ≤ 52 dB(A) Configure
DFS-I-22 1,400 – 2,500 m³/h
220 – 500 Pa
1,400 r/min 0.37 kW ≤ 55 dB(A) Configure
DFS-I-25 1,800 – 2,900 m³/h
250 – 580 Pa
1,400 r/min 0.55 kW ≤ 58 dB(A) Configure
DFS-I-28 2,200 – 3,400 m³/h
280 – 650 Pa
1,400 r/min 0.75 kW ≤ 60 dB(A) Configure
DFS-I-30 2,600 – 3,900 m³/h
300 – 720 Pa
1,400 r/min 1.10 kW ≤ 62 dB(A) Configure
DFS-I-37 3,200 – 4,500 m³/h
350 – 850 Pa
1,400 r/min 1.50 kW ≤ 65 dB(A) Configure
03 / Selection Tradeoffs

DFS vs. DFX Fan Box vs. 4-72 Scroll Centrifugal

Understanding when to specify compact DFS duct fans versus full-size DFX acoustic cabinets or heavy-duty 4-72 scroll fans.
Tradeoff 01 / Spatial Envelope

DFS vs. DFX: Shallow Ceiling Void vs. Double-Skin Cabinet

DFX fan boxes feature heavy double-skin insulated panels, providing superior casing breakout acoustic attenuation for high-spec mechanical rooms.

However, DFX cabinets are taller. When the ceiling void depth is less than 500 mm, DFS duct fans fit directly where DFX cabinets cannot physically be installed.

Ceiling void depth comparison
Tradeoff 02 / Maximum Pressure Head

DFS vs. 4-72: In-Line Casing vs. Heavy-Duty Volute

DFS provides up to 850 Pa static pressure for commercial distribution ducts. If the system involves extensive process equipment, industrial cyclone collectors, or multi-branch riser networks exceeding 1,000 to 3,000 Pa, the 4-72 industrial scroll fan is required.

Industrial scroll volute fan vs in-line duct fan
04 / Procurement Protocol

What Project Inputs Are Required for DFS Duct Fan Sizing?

Essential sizing parameters to confirm before specifying DFS-I low-profile duct centrifugal models.
Engineering Sizing Checklist

10 Key Inputs for DFS Duct Fan Sizing

Submitting your required airflow, calculated branch duct resistance, and available ceiling clearance allows our team to confirm model selection and provide dimensioned CAD submittals.

1. Required Airflow (m³/h / CFM)
2. Required Static Pressure (Pa ΔPs)
3. Available Ceiling Plenum Height Clearance (mm)
4. Connecting Rectangular Duct Dimensions (W × H)
5. Maximum Room Sound NC / dB(A) Rating
6. Power Supply (220V Single-Phase / 380V 3-Phase)
7. Operating Air Temperature (°C)
8. Speed Control: 3-Speed Switch vs VFD
9. Hanging Rod Vibration Isolator Requirements
10. Bottom Drop-Out Service Access Clearance
05 / Quality Control

YONGFAN DFS Duct Fan Fabrication & Aero Balancing

Heavy-gauge galvanized casings, forward-curved multi-blade impellers, and dynamic balancing guarantee low vibration in suspended ceilings.
Precision Forming

Galvanized Sheet Casings

Casings are precision laser-cut and seam-locked from high-yield galvanized sheet steel, providing high rigidity and rust protection in humid ceiling spaces.

ISO 1940

Forward-Curved Impellers

Double-inlet forward-curved centrifugal wheels are dynamically balanced to ISO 1940 G2.5, minimizing structure-borne ceiling vibration.

Maintenance

Bottom Drop-Out Assembly

Motor and impeller core assembly unbolts from the bottom panel, allowing full maintenance without disconnecting adjacent ductwork.

Inspection

100% Run-Test & Acoustic Log

Full electrical current, acoustic sound power, and bearing alignment undergo 100% factory verification prior to dispatch.

Submittal Documentation: Certified static pressure curves, dimensioned CAD/BIM drawings, and wiring diagrams provided on request. Configured Dispatch: Quoted according to DFS-I model size, motor voltage, and speed control accessories.
06 / Technical Q&A

Duct Centrifugal Fans Frequently Asked Questions

Direct engineering answers covering DFS models, ceiling void clearances, noise control, and direct vs cabinet comparison.

What is the documented performance range of the DFS-I Series?

The DFS-I series covers 300 to 4,500 m³/h airflow and 120 to 850 Pa static pressure across models DFS-I-12 through DFS-I-37.

Why choose DFS instead of a standard DFX fan box?

Choose DFS when ceiling void height is restricted (< 500 mm). DFS features an ultra-low profile in-line casing that fits directly into shallow plenums.

How is maintenance performed on suspended DFS fans?

DFS features a bottom drop-out motor and wheel assembly. Technicians can service or replace the core motor from below without dismantling connected duct flanges.

What duct connections are used on DFS fans?

DFS fans feature integrated rectangular duct flanges on both the inlet and discharge for direct bolting to standard rectangular galvanized ductwork.

Can DFS fans be used with speed controllers?

Yes. DFS fans support multi-speed stepped switching (High/Med/Low) or continuous VFD frequency modulation depending on motor type.

What noise levels do DFS fans produce?

Published noise ratings range from ≤45 dB(A) on smaller units (DFS-I-12) to ≤65 dB(A) on large units (DFS-I-37) at rated duty.

Can DFS handle kitchen grease or high-temperature air?

Standard DFS handles clean air up to 60 °C. For hot greasy kitchen exhaust, specify SJG Cabinet Fans or T35-11 Bifurcated Fans with external motors.

Are DFS fans suitable for multi-room toilet extract?

Yes. Models DFS-I-15 through DFS-I-22 are widely specified for multi-room hotel ensuite and commercial restroom extract headers.

07 / Application Engineering Handoff

Select the Right DFS Duct Centrifugal Fan for Your Ceiling Void

Send your required airflow, calculated static pressure, available ceiling clearance, and acoustic limits — our application engineers will confirm the optimal DFS-I model and provide complete technical submittals.

Airflow (300 – 4,500 m³/h) Static Pressure (120 – 850 Pa) DFS-I-12 to DFS-I-37 Ultra-Low Profile Depth Rectangular Duct Flanges 220V / 380V / 50Hz
YONGFAN application engineers reviewing DFS duct fan drawings
Direct Technical Selection Support
Static pressure curves, ceiling clearance drawings & 3D BIM models.