Fan Coil Thermostats | YONGFAN
Room FCU Control · DA Valve-Only · DB 3-Speed Fan · K206 Mechanical 24V

Fan Coil Thermostats: Matched to Fan Sequence, Voltage & Valve Logic

A thermostat with the wrong fan sequence, voltage or valve output can turn a simple FCU installation into rewiring, transformer changes and repeated commissioning visits.

Compare YONGFAN electronic LCD thermostats (DA valve-only, DB valve + 3-speed fan) and mechanical dial thermostats (K206 with built-in master switch and 220 V to 24 V step-down output) across AC 180–260 V, ±1 °C accuracy, and standard 86 wall-box formats.

DA (K-01) Valve Only (Fan Indep)
DB (K Series) Valve + 3-Speed Fan
K206 Dial 220V In → 24V Out
Accuracy ±1 °C · 5–35 °C
YONGFAN K08 digital fan-coil thermostat
Terminal Temperature & Fan Sequencing LCD Electronic · Synchronized 3-Speed Fan · Mechanical Dial · 220V/24V Voltage Conversion
01 / Control Logic Analysis

Thermostat Mismatches Show Up as Control-Sequence Problems

The room reaches setpoint, the valve closes, but the fan keeps running—or both stop together when continuous ventilation was required.
YONGFAN K04 touch-screen fan-coil thermostat
Terminal Control Behavior

Why Output Logic Is the Critical Ordering Field

Per IEC 60730-2-9 Standards for temperature-sensing controls, switching differentials, contact load ratings, and operating sequences determine room comfort and electrical safety.

DA vs DB Fan Sequence Confusion

Specifying a valve-only thermostat (DA) where occupant control of 3-speed fan is needed leaves the fan running on fixed speed at setpoint.

Impact: Missing fan speed controls & uncomfortable room draft

Supply Voltage vs Actuator Mismatch

Wall boxes provide 220 V mains, but valve actuators require 24 V. K206 converts voltage internally; DA/DB require matching line-voltage coils.

Impact: Blown actuator motors or expensive added transformers

2-Wire vs 3-Wire Valve Wiring

Thermostat outputs must match the valve drive: spring-return 2-wire vs driving open/close 3-wire synchronous motors.

Impact: Valve fails to open or motor stalls against end stop

Wall-Box Fit vs Electrical Fit

All units fit standard 86 wall boxes (60 mm pitch), but mechanical fit does not guarantee electrical compatibility with existing wiring.

Impact: Site rewiring delays during hotel/office retrofits

The Three Key Thermostat Selection Decisions

Confirm control sequence at setpoint, supply/actuator voltage, and 2-wire vs 3-wire valve wiring.

01 / Sequence Valve only (DA) vs Valve + 3-Speed Fan synchronous stop (DB)
02 / Interface 220 V line voltage vs 24 V step-down conversion (K206)
03 / Wiring 2-wire (spring return) or 3-wire (open/close/common) valve drive
04 / Fitment Standard 86×86 mm junction box with 60 mm mounting pitch
02 / Portfolio Showcase

Fan Coil Thermostat Product Families

Detailed engineering review of YONGFAN’s electronic LCD and mechanical dial room thermostats for fan coil units.
01 · DA (K-01) Series Electronic LCD · Valve Only

DA (K-01) Valve-Only FCU Thermostat

Opens or closes the 2-wire or 3-wire motorized water valve based on room temperature, while fan operation remains completely independent (controlled separately by schedule, local switch, or central BAS).

Control Action
Motorized Valve Only (Fan Indep)
Supply Voltage
AC 180–260 V, 50/60 Hz (<1 W)
Sensor & Range
NTC · 5–35 °C · ±1 °C
Output Relay
Motorized Valve Load <300 W
Application Fit

Hospitals, hotels, and offices where continuous air circulation and ventilation must continue after room setpoint is satisfied.

02 · DB (K Series) Electronic LCD · Valve + 3-Speed Fan

DB (K Series) Valve & Fan Synchronous Thermostat

Combines room temperature motorized valve control with a 3-speed fan selector (High/Med/Low/Auto). When room setpoint is satisfied, both water flow and fan operation can stop together, saving energy and terminal runtime.

Control Action
Valve + 3-Speed Fan Synchronous
Supply Voltage
AC 180–260 V, 50/60 Hz (<1 W)
Sensor & Range
NTC · 5–35 °C · ±1 °C
Housing & Pitch
Flame-Retardant 86×86 mm · 60 mm
Application Fit

Apartments, hotel guestrooms, and standard commercial offices where occupants expect one wall device to manage temperature and fan speed.

03 · K206 Series Mechanical Dial · 220V to 24V Output

K206 Mechanical Thermostat with 24V Voltage Conversion

Rotary dial mechanical room thermostat featuring a built-in master power isolation switch and a documented 220 V input to 24 V step-down output for direct connection to 24 V motorized valves without external transformers.

Control Type
Mechanical Dial + Master Switch
Power Input / Output
AC 220 V In → AC 24 V Out
Setpoint Range
10–30 °C Std (5–35 °C Adj)
Load Rating
≤16 A Resistive · IP40 Enclosure
Application Fit

Institutional and public facilities requiring robust, tamper-resistant mechanical dials, local power shutoff, and 24 V valve coil power.

03 / Model Selection

Fan Coil Thermostat Comparison Matrix

Directly compare YONGFAN DA, DB, and K206 thermostat families by control type, fan sequencing, valve role, supply voltage, and ordering distinctions.
Variant Control Type Fan Control Valve / Control Role Supply Voltage Setpoint Range Accuracy Key Ordering Distinction
DA (K-01) Electronic LCD Fan Independent 2-wire / 3-wire motorized valve control AC 180–260 V, 50/60 Hz 5–35 °C ±1 °C Choose when thermostat controls water valve only
DB (K Series) Electronic LCD 3-Speed Fan + Auto Motorized valve + fan synchronous control AC 180–260 V, 50/60 Hz 5–35 °C ±1 °C Choose when valve and 3-speed fan are controlled together
K206 Mechanical Rotary Dial Separate Selector (K207/8) Room control with master switch + AC 24 V output AC 220 V ±10% 10–30 °C std (5–35 °C adj) ±1 °C Choose when mechanical control & 220 V-to-24 V conversion are needed
04 / Procurement Protocol

Information Required for Thermostat Selection

Provide FCU control schematic, supply voltage, fan speed requirements, motorized valve wiring, and wall junction box pitch.
STEP 01

Control Sequence

Specify Valve-Only (DA) or Valve + 3-Speed Fan synchronous shutdown (DB).

STEP 02

Supply & Valve Voltage

Available wall voltage (220 V) and matched valve actuator voltage (220 V vs 24 V).

STEP 03

Valve Drive Wiring

Confirm 2-wire spring return or 3-wire floating/directional open-close control.

STEP 04

Format & Aesthetics

Standard 86×86 mm box, 60 mm pitch, custom faceplate branding or colors.

Engineering Handoff

Submit Project Data for Fan Coil Thermostat Quotations

YONGFAN controls engineers will review wiring schedules, verify valve load ratings, and confirm lead times for stock and custom OEM faceplates.

Thermostat Logic: DA vs DB vs K206
Supply Voltage: AC 180–260 V Mains
Actuator Voltage: 220 V vs 24 V
Valve Wiring: 2-Wire vs 3-Wire
Fan Speeds: 3-Speed + Auto
Standard 86 Wall Box (60 mm Pitch)
05 / Manufacturing QA

PCB Surface Mount & NTC Thermal Calibration

Electronic and mechanical thermostat lines undergo automated optical inspection, powered burn-in aging, and thermal bath calibration.
SMT QA

AOI Optical Inspection

Every electronic PCB undergoes automated optical inspection to verify solder joints, component alignment, and traces.

Burn-in QA

100% Powered Aging Test

Finished electronic thermostats are powered on test racks for continuous operational cycling before final calibration.

Thermal QA

Reference Probe Verification

NTC temperature sensors are tested against precision calibrated reference probes to enforce the published ±1 °C accuracy.

Safety QA

Hi-Pot & Relay Cycling

High-voltage dielectric withstand tests and relay load-break tests are performed on 100% of production lots.

Stock Dispatch: Standard DA, DB, and K206 models available in 3–10 working days. OEM Customization: Custom faceplate artwork and language configurations in 15–25 working days.
06 / Engineering Knowledge

Fan Coil Thermostats FAQ

Direct engineering answers regarding fan sequencing, voltage conversion, retrofit replacement, and lead times.

Which thermostat keeps the fan running after reaching setpoint?

Choose DA (K-01) when the thermostat should close the motorized water valve while leaving fan operation independent. Choose DB (K Series) if the fan should stop with the valve.

Which YONGFAN thermostat controls three fan speeds?

DB (K Series) controls a 3-speed fan (High/Med/Low/Auto) together with the motorized valve. The documented K206 dial uses a separate switch (K207/K208).

Which thermostat works directly from 230 V mains?

Electronic DA and DB platforms operate across AC 180–260 V, 50/60 Hz. K206 uses AC 220 V ±10%.

Can K206 replace a separate 24 V step-down transformer?

Yes. K206 accepts 220 V input and provides a documented AC 24 V output to power 24 V motorized valve coils directly.

What thermostat should I choose for a retrofit?

Identify old supply voltage, fan wire count, valve wiring (2-wire vs 3-wire), and sequence at setpoint. DA, DB, and K206 all fit standard 86 wall boxes.

Do DA and DB use the same temperature range?

Yes. Both electronic families cover a 5 to 35 °C setpoint range with ±1 °C control accuracy.

What is the normal lead time for YONGFAN thermostats?

Stock DA/DB units ship in 5–10 working days; K206 in 3–7 days; OEM customized faceplates in 15–25 days after artwork approval.

Are networking protocols standard on these thermostats?

No. Standard models provide standalone room control. Centralized BACnet or Modbus integration must be confirmed as a specific project option.

07 / Application Boundaries

Fan Coil Thermostat Engineering Boundaries

Understanding the functional boundaries between local FCU room thermostats and centralized building automation systems.
Boundary 01 / DDC Panels

Not an AHU Controller

Room thermostats are for terminal FCU space control. AHU duct-temperature PID loops require dedicated DDC controllers.

Boundary 02 / Fan Control

DA Lacks Fan Speed

DA (K-01) controls the valve only. Do not specify DA where the occupant expects wall-mounted fan speed selection.

Boundary 03 / Process Loops

Not for Lab / Process

K206 and DA/DB are engineered for commercial HVAC comfort. Process loops require high-precision RTD/PID instrumentation.

Boundary 04 / Valve Matching

Check Valve Voltage

A thermostat cannot correct a mismatched valve. Always match thermostat output voltage and wiring to the valve actuator.

08 / Engineering Handoff

Select the Right Fan Coil Thermostat for Your Project

Send your FCU equipment schedule, fan speed requirements, motorized valve models, and wall voltage. YONGFAN application engineers will verify wiring compatibility, load capacity, and supply complete wiring submittals.

DA (K-01) Valve-Only DB (K Series) 3-Speed Fan K206 Mechanical 220V/24V AC 180–260 V Mains 5–35 °C · ±1 °C Accuracy Standard 86 Wall Box