Hydraulic Control Valves 100X–900X | YONGFAN
Pilot-Operated Hydraulic Control · 100X–900X · DN50–DN1200+ · PN1.0/1.6/2.5 MPa

Hydraulic Control Valves: 100X–900X Pilot-Operated Systems

Pilot-operated hydraulic control valves solve different water-system problems by changing the pilot circuit—not by treating one valve body as a universal function.

Compare YONGFAN 100X Remote Float, 200X Pressure Reducing, 300X Slow-Closing Check, 400X Flow Control, 500X Relief/Sustaining, 600X Electric, 700X Pump Control, 800X DP Bypass, and 900X Emergency Shut-Off valves (Diaphragm ≤DN450, Piston ≥DN500, PN1.0/1.6/2.5 MPa, 0–80 °C water).

9 Pilot Functions 100X to 900X Variants
Construction Diaphragm / Piston Type
Pressure Grades PN 1.0 / 1.6 / 2.5 MPa
Size Range DN50 to DN1200+ Large
Large flanged hydraulic control valve with pilot tubing installed on municipal pumping station main
Pipeline-Powered Pilot Control Level · Pressure Reduction · Surge Check · Pump Start/Stop · DP Bypass
01 / Hydraulic System Analysis

Hydraulic Control Starts With the Function, Not Nominal Diameter

A main valve body carries water flow, but the small pilot circuit determines whether it reduces pressure, prevents water hammer, balances bypass, or controls tank level.
Hydraulic control valve pilot copper tubing, needle valves and strainers in high rise pump room
Pilot Circuit Operating Principles

Why Main Valve and Pilot Perform Different Jobs

Water pressure in the pipeline provides operating power to the upper control chamber. Diaphragm construction (≤DN450) and piston construction (≥DN500) provide smooth throttling without external power.

Confusing 300X Check with 700X Pump Control

300X provides slow-closing backflow prevention; 700X coordinates full start/stop timing electrically with pump motors to prevent surges.

Impact: Pump motor overload on start or severe water hammer on trip

PRV Cavitation from Excessive Single-Stage Drop

Forcing a single 200X valve to absorb high-rise pressure drops exceeding 4:1 ratios causes violent cavitation, noise, and seat erosion.

Impact: Staged pressure reduction required for high head

Debris Plugging Pilot Orifices

Omitting regular inspection of the small pilot strainer allows pipe scale to clog needle valves, freezing the main valve in open or shut position.

Impact: Loss of automatic regulation & overpressurization

Diaphragm vs Piston Kit Confusion

Maintenance teams ordering diaphragm rebuild kits for DN500+ valves that use internal piston cylinder architecture.

Impact: Incompatible spare parts & prolonged plant downtime

The Shared 100X–900X Engineering Platform

Common flanged main valve body (PN 1.0 / 1.6 / 2.5 MPa, 0–80 °C water) configured with application-specific pilot circuits.

DN50 – DN450 Diaphragm construction with flexible elastomeric control chamber
DN500 – DN1200+ Piston cylinder construction engineered for heavy hydraulic loads
Self-Powered Operates entirely on line water pressure (except 600X electric pilot)
Serviceable Pilots Pilot circuit can be isolated and serviced without removing main body
02 / Portfolio Showcase

Hydraulic Control Valve Product Families (100X–900X)

Detailed engineering review of YONGFAN’s nine pilot-operated hydraulic control valve functions for water distribution and HVAC systems.
100X · Level Control Remote Float Pilot

100X Remote Control Float Valve

Controls water level at tank inlets automatically. A remote float pilot in the tank vents or pressurizes the main control chamber to open or close the main valve as water levels rise and fall without external electrical wiring.

Controlled Variable
Tank Water Level (High/Low)
Pilot Type
Hydraulic Remote Float Pilot
System Location
Roof Tank / Basement Sump Inlet
Power Needed
Zero (Line Water Pressure)
Primary Applications

Roof storage tanks, basement cisterns, high-rise domestic water systems, and process water reservoir level management.

200X · Pressure Reduction Stable Downstream Pressure

200X Pressure Reducing Valve

Regulates fluctuating high upstream pressure down to a steady, preset downstream pressure. The adjustable pilot continuously senses outlet pressure, throttling the main valve to maintain precise pressure regardless of flow demand.

Controlled Variable
Downstream Pressure Setpoint
Pilot Type
Direct-Acting Pressure Reducing Pilot
System Location
High-Rise Risers / Pressure Zones
Pressure Ratio
Recommended Staging for >4:1 Drop
Primary Applications

High-rise domestic water zoning, district municipal water distribution, and downstream plumbing fixture overpressure protection.

300X · Surge Check Slow-Closing Water Hammer Check

300X Slow-Closing Check Valve

Combines backflow prevention with controlled, cushioned closing at pump shutdown. The pilot circuit controls the rate of control chamber filling so the main valve closes smoothly without slamming or creating destructive pressure transients.

Controlled Variable
Controlled Closing Rate & Check
Closing Stages
Quick-Close (90%) + Slow-Close (10%)
System Location
Large Pump Discharge Headers
Hammer Protection
Eliminates Valve Slam Shockwaves
Primary Applications

Pumping stations, high-rise water booster pump rooms, and long municipal pipelines prone to pump-trip water hammer.

400X · Flow Limitation Constant Flow Pilot

400X Flow Control Valve

Limits maximum flow to a calibrated setpoint using a differential-pressure sensing orifice pilot. As network pressure rises, the main valve modulates toward closed to prevent branch overflow in large distribution systems.

Controlled Variable
Maximum Pipe Flow Rate (m³/h)
Pilot Type
Orifice ΔP Flow Pilot
System Location
Large Hydronic & Municipal Branches
Distinct From
Large Main Valve (vs EDV terminal PICV)
Primary Applications

Constant-flow district heating/cooling branches, municipal supply boundaries, and industrial process water loops.

500X · Relief / Sustaining Upstream Pressure Protection

500X Pressure Relief / Sustaining Valve

In relief duty, opens quickly when upstream pressure exceeds setpoint to discharge excess pressure; in sustaining duty, throttles to guarantee minimum upstream pressure before allowing water flow downstream.

Controlled Variable
Upstream Pressure (Min or Max)
Relief Mode
Fast Open on Overpressure Surge
Sustaining Mode
Preserves Critical Upstream Head
Pilot Spring
Adjustable Spring-Loaded Pilot
Primary Applications

Pump overpressure relief bypass lines, high-pressure transmission line protection, and prioritized upstream zone sustaining.

600X · Electric Remote Solenoid-Driven Pilot

600X Electric Control Valve

Adds an external electrical solenoid pilot to the hydraulic main valve platform. Allows large-diameter valves to be opened, closed, or staged from remote BMS/PLC electrical commands using pipeline water pressure for stroke power.

Controlled Variable
Remote Electric On/Off Command
Pilot Type
Solenoid Valve Pilot (220V / 24V)
Operating Energy
Hydraulic Water (Pilot Electric)
Manual Control
Local Manual Override Included
Primary Applications

Automated pump station discharge isolation, remote tank filling, centralized plant isolation, and SCADA-linked mains.

700X · Pump Control Interlocked Start / Stop Timing

700X Pump Control Valve

Interlocks opening and closing sequences directly with pump motor start/stop circuits. Opens slowly after the pump starts against closed head and closes slowly before motor de-energization to prevent hydraulic shockwaves.

Controlled Variable
Pump Start / Stop Coordination
Interlock Signals
Motor Contactor / VFD Sync Contacts
Closing Logic
Slow-Closes Prior to Motor Shutdown
Surge Control
Zero Reverse Flow & Hammer Elimination
Primary Applications

Municipal booster pumping stations, commercial high-rise pump rooms, and deep-well water supply headers.

800X · DP Bypass System Differential Pressure Bypass

800X Differential Pressure Bypass Balancing Valve

Senses supply-to-return differential pressure across central HVAC headers. As 2-way terminal valves close and system ΔP rises, 800X opens a bypass path to protect chillers and pumps from minimum flow starvation.

Controlled Variable
System Supply-to-Return ΔP
Pilot Type
Dual Sensing Line DP Pilot
System Location
Central Chilled-Water Bypass Header
Chiller Protection
Maintains Minimum Evaporator Flow
Primary Applications

Variable-flow chilled-water systems, district HVAC plants, and central primary/secondary hydronic decoupling loops.

900X · Fire Emergency Pressure-Triggered Emergency Supply

900X Emergency Shut-Off / Supply Valve

Engineered for fire-protection water mains (referenced to GB 25201 framework). Senses downstream pressure drops from opened hydrants or sprinkler release, opening immediately to prioritize fire-water flow over domestic branches.

Controlled Variable
Pressure-Drop Triggered Emergency State
Trigger Action
Opens on Fire-Water Demand Drop
System Location
Combined Domestic/Fire Supply Mains
Compliance
GB 25201 Referenced Framework
Primary Applications

Combined commercial domestic/fire water supply networks, industrial plant fire headers, and municipal emergency zoning.

03 / Selection Routing

100X–900X Hydraulic Valve Selection Matrix

Compare all nine YONGFAN pilot-operated hydraulic control valve variants by controlled function, energy source, typical location, and critical first selection inputs.
Model Controlled Function Standard Energy Source Typical System Location First Data to Confirm
100X Tank water level Water pressure + remote float Tank inlet header Tank depth, fill flow, inlet pressure
200X Downstream pressure Water pressure + PRV pilot Riser / pressure zone Inlet & required outlet pressure, flow
300X Slow-closing check Water pressure + pilot timing Pump discharge header Pump flow, static head, closing timing
400X Flow rate limitation Differential pressure & orifice pilot Large distribution branch Required flow limit & available ΔP
500X Relief / sustaining pressure Spring-loaded pilot + water pressure Main / bypass header Relief or sustaining pressure setpoints
600X Remote electric control External electric pilot + hydraulic main Automated main isolation Supply voltage, signal & fail position
700X Pump start/stop coordination Water pressure + motor interlock timing Pump discharge header Pump motor sequence & head curve
800X Differential-pressure bypass Pressure difference across sensing ports HVAC chiller bypass ΔP setpoint & maximum bypass flow
900X Pressure-triggered emergency Hydraulic pressure-drop pilot Fire-water supply main Normal/trigger sequence & fire approvals
04 / Procurement Protocol

Information Required for Hydraulic Valve Sizing

Submit functional model, nominal pipe DN, flange standard, pressure class, design flow range, and pilot setpoint parameters.
STEP 01

Functional Variant

Select 100X (Level), 200X (PRV), 300X (Check), 500X (Relief), 700X (Pump), 800X (Bypass).

STEP 02

Pipe DN & Flange

Nominal diameter (DN50–DN1200+), flange standard (GB/DIN/ANSI), and PN1.0/1.6/2.5 MPa.

STEP 03

Flow & Pressure

Normal, minimum, and peak flow rates (m³/h) and inlet/outlet pressure ranges.

STEP 04

Pilot Setpoints

Target downstream pressure, relief pressure, pump electrical interlock, or ΔP setpoint.

Engineering Handoff

Submit Hydronic Data for 100X–900X Valve Sizing

YONGFAN hydraulic engineers will verify velocity limits, calculate cavitation indices for 200X, size slow-close timing for 300X/700X, and provide full submittal drawings.

Model: 100X through 900X
Pipe DN (DN50 to DN1200+)
Flange Standard: GB, DIN, ANSI
Pressure Class: PN1.0 / 1.6 / 2.5 MPa
Flow Range: Min, Normal, Peak m³/h
Controlled Pressure / ΔP Setpoint
05 / Manufacturing QA

Pilot Bench Calibration & Size-Band Lead Times

Every valve undergoes 1.5× hydrostatic shell testing, 1.1× seat sealing tests, and function-specific pilot circuit calibration before crating.
Pressure QA

1.5× Shell Hydro Test

Ductile-iron bodies undergo 1.5× nominal pressure shell verification per EN 12266-1, API 598, and GB/T 13927.

Sealing QA

1.1× Seat Leakage Test

Resilient valve seats and pilot control chambers are pressurized to 1.1× nominal pressure to certify zero drop-through.

Pilot QA

Functional Loop Calibration

Pilots are calibrated on test loops: 100X float levels, 200X pressure stability, 300X closing time, and 800X ΔP response.

Coating QA

Fusion-Bonded Epoxy

Internal and external surfaces receive electrostatic fusion-bonded epoxy powder coating tested for thickness and pinholes.

Documented Manufacturing Lead Times by Valve Size Band

Size Band Construction Documented Lead Time Packaging / Logistics
DN50 – DN200Diaphragm Type15 – 25 Working DaysExport Wooden Crating
DN250 – DN500Diaphragm / Piston30 – 45 Working DaysHeavy-Duty Sea Crates
DN600 – DN1200Piston Type45 – 70 Working DaysCustom Structural Palletizing
DN1400+Heavy PistonConfirm by Project RFQStaged Project Shipping
Project Logistics: Sea-freight wooden crating standard for DN100+. Trade terms: EXW, FOB, CIF, DDP. Submittal Package: Hydrostatic test certificates, pilot calibration curves, and dimensional GA drawings provided.
06 / Engineering Knowledge

Hydraulic Control Valves FAQ

Direct engineering answers regarding power requirements, diaphragm vs piston construction, 300X vs 700X, and fire approvals.

Do 100X–900X valves require electrical power?

Most variants do not. The 100X, 200X, 300X, 400X, 500X, 700X, 800X, and 900X use line water pressure for operation. The 600X uses external electric solenoid control.

When is diaphragm vs piston construction used?

YONGFAN uses DN50–DN450 diaphragm construction and DN500 and above piston construction for the shared hydraulic control platform.

What pressure classes are available?

The shared platform is documented in PN 1.0 MPa, PN 1.6 MPa, and PN 2.5 MPa pressure grades.

What is the standard working-temperature range?

The published standard operating range is 0 to 80 °C for water. Applications above 80 °C require specialized trim and sealing review.

What is the difference between 300X and 700X?

300X is a hydraulic slow-closing check valve for backflow surge prevention. 700X coordinates opening and closing sequences electrically with pump motor start/stop.

What is the difference between 400X and 800X?

400X regulates branch flow rate. 800X regulates a bypass loop based on differential pressure between supply and return headers.

Can 800X replace a normal hydronic balancing valve?

No. DRV, KPF, and BYF balance branch resistance. 800X is a pilot-operated bypass valve that maintains system-level ΔP across central chiller headers.

Can pilot circuits be serviced without removing the main valve?

Yes. The pilot tubing and pilot valves can be isolated via small shutoff cocks and serviced while the main valve body remains bolted in the pipeline.

07 / Application Boundaries

Hydraulic Control Valve Engineering Boundaries

Understanding operational boundaries between large hydraulic control valves, manual isolation, and small terminal controls.
Boundary 01 / Manual Isolation

Not Simple Shut-Off

Do not purchase 100X–900X valves solely for manual shut-off; use standard gate, ball, or butterfly valves for basic isolation.

Boundary 02 / Terminal Coils

Not Terminal Valves

FCU and AHU coil control requires motorized control valves. 100X–900X valves are engineered for large plant and distribution mains.

Boundary 03 / Branch Balancing

800X vs Branch Valves

800X regulates header bypass; it does not balance individual hydronic coils. Specify DRV/BYF balancing valves on branch circuits.

Boundary 04 / Fire Approvals

900X Fire Verification

Verify project-specific fire authority approvals (CCCF, UL/FM, GB 25201) before approving 900X emergency fire-water valves.

08 / Engineering Handoff

Configure Your 100X–900X Hydraulic Control Valve

Send your pipeline DN, required hydraulic function (level, pressure, surge check, pump control, or bypass), design flow rates, and operating pressures. YONGFAN application engineers will verify sizing, calculate pilot settings, and supply complete submittal drawings.

100X Float · 200X PRV · 300X Check 400X Flow · 500X Relief · 600X Electric 700X Pump Control · 800X DP Bypass Diaphragm ≤DN450 · Piston ≥DN500 PN 1.0 / 1.6 / 2.5 MPa Classes Fusion-Bonded Epoxy Coated
YONGFAN hydraulic engineers reviewing large pilot operated hydraulic control valve schematics
Direct Application Engineering Support
Pilot circuit design, cavitation calculations & GA drawings.